xixiliguo 3e807112fd ss: fix expired time format of timer
When expired time of time-wait timer is less than or equal to 9 seconds,
as shown below, result that below 1 sec is incorrect.
Expect output should be show 9 seconds and 373 millisecond, but 9.373ms
mean only 9 millisecond and 373 microseconds

Before:
TIME-WAIT 0      0     ...    timer:(timewait,12sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,11sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,10sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,9.373ms,0)
TIME-WAIT 0      0     ...    timer:(timewait,8.679ms,0)
TIME-WAIT 0      0     ...    timer:(timewait,1.574ms,0)
TIME-WAIT 0      0     ...    timer:(timewait,954ms,0)
TIME-WAIT 0      0     ...    timer:(timewait,303ms,0)

After:
TIME-WAIT 0      0     ...    timer:(timewait,13sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,12sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,10sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,9.501sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,8.990sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,7.865sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,1.098sec,0)
TIME-WAIT 0      0     ...    timer:(timewait,476ms,0)

Signed-off-by: xixiliguo <xixiliguo@foxmail.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
2024-07-25 10:37:53 -07:00
..
2020-01-20 09:43:22 -08:00
2024-05-23 09:27:55 -07:00
2024-05-23 09:27:55 -07:00
2023-01-14 09:00:34 -08:00
2020-08-03 10:02:47 -07:00
2020-05-13 14:28:38 +00:00
2024-05-23 09:27:55 -07:00
2024-05-23 09:27:55 -07:00
2023-01-14 09:00:34 -08:00
2024-07-25 10:37:53 -07:00
2023-01-14 09:00:34 -08:00
2023-01-14 09:00:34 -08:00